DEN-1B, MCFARLAND DENSITOMETER
- Brand: Biosan
- SKU: 196-0285
- HSN Code: 9027 9090
- County of Origin: LATVIA
- Product Code: BS-050104-AAF
- Availability: In Stock
-
Speak to our Expert 1800 103 6641
Biosan DEN-1B, McFarland densitometer includes A-16 adapter for 16 mm tubes, external power supply unit with 230VAC 50/60Hz Euro plug.
- Densitometer is designed for measurement of cell suspension's turbidity in the range of 0.0–6.0 McFarland units (0 – 180×107 cells/ml).
- Densitometers provide the opportunity to measure solution turbidity in a wider range (up to 15.0 McFarland units) however, it is necessary to remember that in this case the standard deviation values increase.
- The operation principle is based on measurement of optical density with digital presentation of results in McFarland units. The unit is calibrated at the factory (for operation with 16 mm diameter glass tubes) and keeps calibration without power supply. However, if necessary it is possible to calibrate the unit by 2–6 points in 0.0–6.0 McFarland unit range. Both commercial standards (e.g. produced by BioMerieux, Lachema, etc.) and the cell suspensions prepared in a laboratory can be used for calibration. Possibility to restore factory calibration settings*
Following calibration kits are available on request:
CKG16-4 for glass tubes with diameter 16 mm (polymer microparticles), set of 0; 0.5; 1.0; 2.0; 3.0; 4.0 McFarland Turbidity Standards;
CKG16-6 for glass tubes with diameter 16 mm (polymer microparticles), set of 0; 0.5; 1.0; 2.0; 3.0; 4.0; 5.0; 6.0 McFarland Turbidity Standards;
CKG18-4 for glass tubes with diameter 18 mm (polymer microparticles), set of 0; 0.5; 1.0; 2.0; 3.0; 4.0 McFarland Turbidity Standards;
CKG18-6 for glass tubes with diameter 18 mm (polymer microparticles), set of 0; 0.5; 1.0; 2.0; 3.0; 4.0; 5.0; 6.0 McFarland Turbidity Standards;
Light source |
LED |
Measurement wavelength
(λ) |
λ = 565 ±15 nm |
Measurement range |
0.00–15.00 McF |
Display resolution |
0.01 McF |
Accuracy, of the full
scale |
±3% |
Measurement time |
1 s |
Sample volume |
not less than 2 ml |
Tube external diameter |
16 mm (using A-16
adapter) or 18 mm (without adapter) |
Possibility to restore
factory calibration settings |
+ |
Display |
LCD |
Overall dimensions
(W×D×H) |
165 × 115 × 75 mm |
Weight |
0.7 kg |
Independent power
supply |
3 × AA batteries |
Input current/power
consumption |
12 V, 7 mA / 0.1 W |
External power supply |
Input AC 100–240 V,
50/60 Hz; Output DC 12 V |
Standard set |
External power supply, A-16 and 3 × AA batteries |