Cooling & Heating

Perhaps the most common types of electrical equipment found in a laboratory are the devices used to supply the heat needed to affect a reaction or separation. These include ovens, hot plates, heating mantles, water baths, oil baths, tubular furnaces. The use of steam-heated devices rather than electrically heated devices is generally preferred whenever temperatures of 100 °C or less are required. Because they do not present shock or spark risks, they can be left unattended with assurance that their temperature will never exceed 100 °C. Laboratory heating and cooling equipment is used to sterilize instruments or provide a controlled environment for temperature-sensitive materials.

PRINCIPLES OF HEAT TRANSFER

Conduction:

Conduction is heat transfer by means of molecular agitation within a material without any motion of the material as a whole.

Convection:

Convection is heat transfer by mass motion of a fluid such as air or water when the heated fluid is caused to move away from the source of heat, carrying energy with it.

Radiation:

Heat transfer due to emission of electromagnetic waves is known as thermal radiation.

Multi-Position Electromantle Integral Control- 3x250ML 230V

Multi-Position Electromantle Integral Control- 3x250ML 230V

Multi-Position Electromantle Integral Control- 3x250ML ELECTROMANTLE 230V UK AND EU PLUGSFeatures1.&..
Multi-Position Electromantle Integral Control- 3x500ML 230V

Multi-Position Electromantle Integral Control- 3x500ML 230V

Multi-Position Electromantle Integral Control- 3x500ML ELECTROMANTLE 230V UK AND EU PLUGSFeatures1.&..
Multi-Position Electromantle Integral Control- 6x1000ML

Multi-Position Electromantle Integral Control- 6x1000ML

Multi-Position Electromantle Integral Control- 6x1000ML ELECTROMANTLE 230V UK AND EU PLUGSFeatures1...
Multi-Position Electromantle Integral Control- 6x100ML 230V

Multi-Position Electromantle Integral Control- 6x100ML 230V

Multi-Position Electromantle Integral Control- 6x100ML ELECTROMANTLE 230V UK AND EU PLUGSFeatures1.&..
Multi-Position Electromantle Integral Control- 6x250ML

Multi-Position Electromantle Integral Control- 6x250ML

Multi-Position Electromantle Integral Control- 6x250ML ELECTROMANTLE 230V UK AND EU PLUGSFeatures1.&..
Multi-Position Electromantle Integral Control- 6x500ML

Multi-Position Electromantle Integral Control- 6x500ML

Multi-Position Electromantle Integral Control- 6x500ML ELECTROMANTLE 230V UK AND EU PLUGSFeatures1.&..
Multi-Volume Metal Mantle Integral Control- 250-1000ML 230V

Multi-Volume Metal Mantle Integral Control- 250-1000ML 230V

Multi-Volume Metal Mantle Integral Control- 250-1000ML MULTI-VOLUME MANTLE 230V UK AND EU PLUGSFeatu..
OMNI Reaction Stations- Combined Kit 10 X 25

OMNI Reaction Stations- Combined Kit 10 X 25

OMNI Reaction Stations- Combined Kit 10 X 25, 230 V EU and UK PlugFeaturesInterchangeable modular de..
OMNI Reaction Stations- Combined Kit 6 x 100, 230 V

OMNI Reaction Stations- Combined Kit 6 x 100, 230 V

OMNI Reaction Stations- Combined Kit 6 x 100, 230 V, UK and EU PlugsFeaturesInterchangeable modular ..
OMNI Reaction Stations- Combined Kit 6 x 250

OMNI Reaction Stations- Combined Kit 6 x 250

OMNI Reaction Stations- Combined Kit 6 x 250, 230 V UK and EU Plugs FeaturesInterchangeable mod..
OMNI Reaction Stations- Combined Kit 6 x 50

OMNI Reaction Stations- Combined Kit 6 x 50

OMNI Reaction Stations- Combined Kit 6 x 50, 230 V UK and EU PlugsFeaturesInterchangeable modular de..
Orbital/linear shaking water bath, digital, 26L, 0* to 99°C

Orbital/linear shaking water bath, digital, 26L, 0* to 99°C

Orbital/linear shaking water bath, digital, 26L, 0* to 99°C, includes clear lid...
Recirculating chiller 1300W standard pump, audible alarm, -10 - 60°C

Recirculating chiller 1300W standard pump, audible alarm, -10 - 60°C

Recirculating chiller 1300 W including standard pump, audible alarm and flow fail cut-out, -10 to 60..
Recirculating chiller 3000W standard pump, audible alarm, -10 - 60°C

Recirculating chiller 3000W standard pump, audible alarm, -10 - 60°C

Recirculating chiller 3000W including standard pump, audible alarm and flow fail cut-out, -10 to 60°..
SBB Aqua Plus Boiling Bath, 12 L

SBB Aqua Plus Boiling Bath, 12 L

Grant SBB Aqua Plus Boiling Bath, 12 L..
SBB Aqua Plus Boiling Bath, 18 L

SBB Aqua Plus Boiling Bath, 18 L

SBB Aqua Plus Boiling Bath, 18 L..
Showing 81 to 96 of 286 (18 Pages)